Applications NoteLogging Data to Internal Memory SurvCE - SF-3050
Rev. A i Release - Apr 11
This guide will step you through logging GNSS receiver data to the SF-3050 internal memory port via Carlson
Software’s SurvCE data collector program. The receiver data may be used for post-processing or troubleshooting.
SurvCE software version 2.30.47 (Beta release) or later is required for this interface
The procedure which follows applies to version 2.0.22.0a or later of SF-3050 firmware
Procedure
Create a data logging command file. A sample
file is provided below:
Data Logging Setup.txt:
[OUTPUT]PANICA,ONCHANGE,,FH1
[OUTPUT]??,ONCHANGE,,FH1
[OUTPUT]OK,ONCHANGE,,FH1
[LOGFILE]A:,START
[OUTPUT]MSGVERSION,ONTIME,600,FH1
[OUTPUT]MSGPRODUCTINFO,ONCE,,FH1
[OUTPUT]MSGPRODUCTINFO,ONTIME,600,FH1
[PROFILE]OUTPUT
[OUTPUT]EPHEM1B,ONCE,,FH1
[OUTPUT]ALM1B,ONCE,,FH1
[OUTPUT]ECHODGPSB,ONCHANGE,,FH1
[OUTPUT]CHNLSTATUS1B,ONTIME,1,FH1
[OUTPUT]PVT1B,ONTIME,1,FH1
[OUTPUT]MEAS1B,ONTIME,1,FH1
[OUTPUT]EPHEM1B,ONCHANGE,,FH1
[OUTPUT]ALM1B,ONCHANGE,,FH1
[OUTPUT]SFSTATUS1B,ONTIME,1,FH1
Copy this file to the data collector
Connect the data collector to the SF-3050 via either the receiver Bluetooth port or Com1 RS-232
Turn the receiver and data collector on and start the SurvCE program
Establish a connection between the data collector and the SF-3050 (either Rover or Base, as appropriate)
Select the Equip tab
Click on GPS Utilities
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Procedure

Applications Note – Logging Data to Internal Memory SurvCE - SF-3050 Rev. A i Release - Apr 11 This guide will step you through logging GNSS receive

Page 2

Applications Note – Logging Data to Internal Memory SurvCE - SF-3050 Rev. A ii Release - Apr 11  Click on Send Command  Enter the foll

Page 3

Applications Note – Logging Data to Internal Memory SurvCE - SF-3050 Rev. A iii Release - Apr 11  The file transfer begins  At the comple

Page 4

Applications Note – Logging Data to Internal Memory SurvCE - SF-3050 Rev. A iv Release - Apr 11  The logged file is located in the datalog direct

Commentaires sur ces manuels

Pas de commentaire